IX83 Inverted Motorized Microscope
IX83 Inverted Motorized Microscope OVERVIEW
The fully-motorized and automated IX83 is designed to satisfy a myriad of research needs. Available as a one-deck system with ergonomic low stage height or as a two-deck system with additional expansion capabilities. Both provide the ability to perform a multitude of imaging techniques, ranging from long term time-lapse imaging and other demanding cutting edge techniques to casual documentation. Innovative new features include:- The New fly-eye fluorescence illuminator produces uniform fluorescence illumination across the field of view even when using new large format cameras.
- The Ultrasonic Motorized, Encoded Stage uses Olympus’ ultrasonic motor stage technology providing precise and repeatable movement with a low-profile, noise-free design.
- A new Zero Drift Compensation autofocus works in stand-alone mode without the need for a connected computer.
- High speed filter wheels, shutters and light sources—allows for the design of a system to meet high speed acquisition requirements.
- The Olympus Real Time Controller allows for microsecond timing accuracy with high speed hardware.
IX83 Inverted Motorized Microscope Specifications
IX83 | IX73 | IX53 | ||
Microscope Frame | Optical System | UIS2 Optical System | ||
Revolving nosepiece | Motorized sextuple revolving nosepiece (DIC slider attachable), simple waterproof structure. | * Motorized sextuple revolving nosepiece (DIC slider attachable), simple waterproof structure. * Coded sextuple revolving nosepiece (DIC slider attachable), simple waterproof structure. |
Sextuple revolving nosepiece, simple waterproof structure. | |
Focus | Stroke: 10.5 mm Minimum increment: 0.01μm, Maximum nosepiece movement speed: 3 mm/s |
Stoke: 10 mm | Stroke: 10 mm | |
Light Path selection | Motorized 0:100/50:50/100:0 (Left side port: BI port) | 0:100/50:50/100:0 (Left side port: BI port) | 50:50 (Left side port: BI port) | |
Transmitted light illuminator | Pillar tilt mechanism (30° inclination angle, with
vibration reducing mechanism), Condenser holder (with 88 stroke,
refocusing mechanism), Field iris diaphragm adjustable, 4 filter holders Light source: * 12 V 100 W halogen bulb (pre-centered) * High color reproductive LED light source |
* 30W halogen illuminator: Detachable condenser lens system (NA
0.3, W.D. 72 mm), single filter holder aperture iris diaphragm
adjustable. *100W halogen illuminator: Pillar tilt mechanism (30° inclination angle, with vibration reducing mechanism), Condenser holder (with 88 mm stroke, refocusing mechanism) Field iris diaphragm adjustable, 4 filter holders. |
||
Observation tube | Widefield (FN 22) | *Widefield tilting binocular * Widefield binocular * Widefield trinocular | *Widefield tilting binocular * Widefield binocular |
|
Stage | Scanning stage with ultrasonic | Stage stroke: X:76 mm x Y: 52 mm, maximum stage movement speed: 30 mm/s | N/A | |
Mechanical stage with right handle | ||||
Right handle stage | ||||
Flexible right handle stage | ||||
Gliding Stage | ||||
Plain Stage | ||||
Condenser | Motorized long working distance condenser | W.D. 27 mm, NA 0.55, motorized turret with 7 position slots for optical devices (3 positions for ø30 mm and 4 positions for ø38 mm), motorized aperture and polarizer. | N/A | |
Long working distance universal condenser | ||||
Long working distance relief contrast | ||||
Ultra long working distance | ||||
Fluorescence Illuminator | L-shape-fluorescence illuminator with flyeye lens | L-shaped design with exchangeable FS module. | N/A | |
L-shape-fluorescence illuminator | L-shaped design with exchangeable FS and AS modules. | N/A | ||
Fluorescence illuminator | Straight design with field iris diaphragm. | |||
Fluorescence Mirror Turret | Motorized fluorescence mirror turret | Motorized turret with 8 positions, built -in shutter, simple waterproof structurer. | N/A | |
Coded fluorescence mirror | N/A | Coded 8 positions turret, built-in shutter, simple waterproof structure | N/A | |
Fluorescence mirror turret | N/A | N/A | Turret with 8 positions, built-in shutter, simple waterproof structure. | |
Fluorescence light source | *130W Hg light guide illumination * 100W Hg apo lamp housing and transformer *100W Hg lamp housing and transformer * 75W Xe lamp housing and transformer. |
|||
Focus Compensator | Z-drift Compensator Class 1 laser device |
offset method (Focus search, one-shot focus, continuous focus) | N/A | |
Filter wheel/shutter | Motorized fast filter wheel | High speed mode 60 ms, low vibration mode 100 ms (rotation time until next hold on the wheel) | N/A | |
Motorized fast filter wheel for emission | High speed mode 60 ms, low vibration mode 100 ms (rotation time until next hold on the wheel) C-mount adapter and bayonet mount adapter are enclosed. | N/A | ||
Motorized fast shutter | High speed mode 26.2 ms, Low vibration mode 60 ms (rotation time on one way). | N/A | ||
Motorized attenuator wheel | Time to shift another filter 300ms (rotation time until next hole on the wheel). | N/A | ||
Operating environment | *Indoor use *Ambient temperature: 5° to 40° C (41° to 104° F) *Maximum relative humidity: 80% for temperatures up to 31°C (88°F), decreasing linearly through 70% at 34°C(93°F), 60% at 37°C (99°F), to 50% relative humidity at 40°C (104°F) *Supply voltage fluctuations: Not to exceed |
KAMI PT. FAJARMASMURNI AGEN RESMI (TUNGGAL) MIKROSKOP OLYMPUS JAPAN WILAYAH INDONESIA KALAU BERMINAT DAN INGIN TAU TENTANG OLYMPUS HUBUNG SAYA
AGUSTIAR-PRODUCT ENGINEER
CP 085260025094 atau
EMAIL : agustiar@fajarmasmurni.com
EMAIL : agustiar@fajarmasmurni.com
atau kunjungi WWW.FAJARMASMURNI.COM